无锌无灰HM液压油和CKC润滑油
无锌无灰HM液压油和CKC润滑油
在过去几年中,无锌液压油逐渐受到欢迎。
在许多情况下,必须使用无锌液压油,尤其是在液压油可能污染金属加工液的机床上。Renolin ZAF B液压油是符合ISO 6743-4的无锌和无灰HM液压油。
Realin ZAF B液压油最重要的特点是:
良好的氧化安定性和良好的耐老化性
强大的极压性能和良好的磨损保护
优良的防腐性能
快速放气,低发泡
破乳性能好
与密封材料相容性好
应用:
Renolin ZAF B产品是符合ISO 6743-4的高等级HM液压油,可用于所有液压系统,也可作为符合ISO 6743-6的齿轮箱、轴承和循环系统中的CKC润滑油。建议在液压油和金属加工液接触的机床上使用Renolin ZAF B产品。
RENOLIN AW |
|
32 |
46 |
68 |
|
Hydraulic oil type |
|
|
|
|
|
acc. to ISO 6743-4 |
|
HM 32 |
HM 46 |
HM 68 |
|
acc. to DIN 51 502 |
|
HLP 32 |
HLP 46 |
HLP 68 |
|
Lubricating oil type |
|
|
|
|
|
acc. to ISO 6743-6 |
|
CKC 32 |
CKC 46 |
CKC 68 |
|
acc. to DIN 51 502 |
|
CLP 32 |
CLP 46 |
CLP 68 |
|
Characteristics |
Unit |
|
|
|
Test method |
Colour |
|
1 |
1 |
1 |
ASTM D 1500 |
Kinematic viscosity |
|
|
|
|
|
at 40 °C |
mm²/s |
31.5 |
45 |
65.4 |
ASTM D 445 |
at 100 °C |
mm²/s |
5.3 |
6.7 |
8.4 |
ASTM D 445 |
Viscosity index |
|
98 |
101 |
98 |
ASTM D 2270 |
Density at 15 °C |
kg/l |
0.878 |
0.878 |
0.885 |
ASTM D 1298 |
Flash point, Cleveland open cup |
°C |
215 |
230 |
230 |
ASTM D 92 |
Pour point |
°C |
-30 |
-27 |
-21 |
ASTM D 97 |
Neutralization number |
mg KOH/g |
0.3 |
0.3 |
0.3 |
ASTM D 974 |
Saponification number |
mg KOH/g |
1.3 |
1.3 |
1.3 |
ASTM D 94 |
Water content |
% mass |
not traceable |
not traceable |
not traceable |
ASTM D 95 |
Insolubles |
% mass |
not traceable |
not traceable |
not traceable |
DIN 51 592 |
Demulsification |
min |
10 |
10 |
15 |
DIN 51 599 |
Air release at 50 °C |
min |
3 |
8 |
7 |
ASTM D 3427 |
Foaming, |
|
|
|
|
|
seq. I |
ml |
30/0 |
50/0 |
50/0 |
ASTM D 892 seq. I-III |
seq. II |
ml |
20/0 |
20/0 |
20/0 |
ASTM D 892 seq. I-III |
seq. III |
ml |
20/0 |
20/0 |
20/0 |
ASTM D 892 seq. I-III |
Copper corrosion |
degree of corr. |
1a-100A3 |
1a-100A3 |
1a-100A3 |
ASTM D 130 |
Rust prevention |
|
pass A |
pass A |
pass A |
ASTM D 665 |
Ageing behaviour, increase in neutralization number after 1000 h |
mg KOH/g |
< 2 |
< 2 |
< 2 |
ASTM D 943 |
Brugger boundary friction test |
N/mm² |
38 |
DIN 51 347 (D) |
|
|
FZG mechanical gear rig test |
load stage |
> 12 |
> 12 |
> 12 |
DIN 51 354-2 |
Vickers vane pump test, loss of mass |
|
|
|
|
|
on ring |
mg |
120 |
120 |
120 |
IP 281 |
on vanes after 250 h |
mg |
30 |
30 |
30 |
IP 281 |
Effect on SRE-NBR 1 seal material acc. to DIN 53 538-1 at 100 °C +/– 1 °C after 7 days +/– 2 hours, |
|